Article

lock Open Access lock Peer-Reviewed

413

Views

ORIGINAL ARTICLE

Transxiphoid approach without sternotomy for the correction of atrial septal defect

Miguel Barbero-MarcialI; Marcelo B JateneI; Carla TanamatiI; Nana Miura IkariI; Edmar AtikI; Munir EbaidI; Geraldo VerginelliI; Adib D JateneI

DOI: 10.1590/S0102-76381996000400011

ABSTRACT

PURPOSE: Evaluate a new access for surgical correction of atrial septal defects. METHODS: The access by xiphoid window was done in 7 cases with atria! septal defect type ostium secundum. The age ranged from 6 months to 14 years, mean-age 5.1 years old. In all cases the extracorporeal circulation was done with femoral artery and right atrial cannulation and aortic clamping. The video-assisted endoscopy was utilized to help the visualization of the aorta, ductus arteriosus and the anatomy of the left intracardiac structures. RESULTS: There was no intraoperative or postoperative complications and in our 7 cases the extubation at the operating room was possible. CONCLUSION: The xiphoid window without opening the sternum permited correction of the atrial septal defect with good results and without complications, and could be used as a new technique, less invasive, to correct these defects.

RESUMO

OBJETIVO: Avaliação de uma nova abordagem cirúrgica para fechamento da comunicação interatrial. MÉTODOS: A abordagem da comunicação interatrial através da janela xifóidea foi realizada em 6 pacientes do sexo masculino e 1 do sexo feminino e a idade variou de 6 meses a 14 anos, com média de idades de 5,1 anos. Em todos, foi utilizada acirculação extracorpórea, através de canulação da artéria femoral e átrio direito e videotoracoscopia para auxiliar a visibilização da aorta e do canal arterial, assim como das estruturas correspondentes às cavidades esquerdas. RESULTADOS: Não houve complicações intra-operatórias ou pós-operatórias e, em todos os pacientes, foi possível a extubação na sala de operações. CONCLUSÃO: A janela xifóidea, sem a abertura do esterno, permitiu a correção da comunicação interatrial com bons resultados, podendo constituir-se em uma nova abordagem, minimamente invasiva.
Full text available only in portuguese PDF format.

REFERENCES

1. Benetti F J & Ballester C - Use of thoracoscopy and a minimal thoracotomy, in mammary-coronary bypass to left anterior descending artery, without extracorporeal circulation: experience in 2 cases. J Cardiovasc Surg 1995; 36: 159-61.

2. Lin P J, Chang C H, Chu J J et al. - Video-assisted mitral valve operations. Ann Thorac Surg 1996; 61: 1781-7.

3. Burke R P, Wernovsky G, van der Velde M, Hansen D, Castañeda A R - Video-assisted thoracoscopy surgery for congenital heart disease. J Thorac Cardiovasc Surg 1995; 109: 499-508.

4. Burke R P & Chang A C - Video-assisted thoracoscopic division of a vascular ring in an infant: a new operative technique. J Thorac Cardiovasc Surg 1993; 8: 537-40.

5. Chang C H, Lin P J, Chu J J et al. - Video-assisted cardiac surgery in closure of atrial septal defect. Ann Thorac Surg 1996; 62: 697-701. [MedLine]

6. Rosengart T K & Stark J F - Repair of atrial septal defect through a right thoracotomy. Ann Thorac Surg 1993; 55: 1138-40. [MedLine]

7. Laks H & Hammond G - A cosmetically acceptable incision for the medial sternotomy. J Thorac Cardiovasc Surg 1980; 79: 146-9. [MedLine]

8. Baucia J A, Ferreira Sobrinho A, Barbero-Marcial M - Incisão submamária para esternotomia mediana. Arq Bras Cardiol 1993; 60: 335-8. [MedLine]

9. Tatebe S, Eguchi S, Miyamura H et al. - Limited vertical skin incision for median sternotomy. Ann Thorac Surg 1992; 54: 787-8. [MedLine]

10. Wilson Jr. W R, Ibawi M N, DeLeon S Y et al. - Partial median sternotomy for repair of heart defects: a cosmetic approach. Ann Thorac Surg 1992; 54: 892-93.

11. Komai H, Naito Y, Fujiwara K et al. - Lower mid-line skin incision and minimal sternotomy: a more cosmetic challenge for pediatric cardiac surgery. Cardiol Young 1996; 6: 76-9.

12. King T D & Mills N L - Secundum atrial septal defect: nonoperative closure during cardiac catheterization. JAMA 1976; 235: 2506. [MedLine]

13. Latson L A, Hofschire P J, Kugler J D et al. - Residual shunts after transcatheter closure of patent ductus arteriosus: a major concern of benign "technomalady"?. Circulation 1991; 84: 2591-3. [MedLine]

14. Rome J J, Keane J F, Perry S B, Spevak P J, Lock J E - Double-umbrella closure of atrial septal defects: initial clinical applications. Circulation 1990, 82: 751-8. [MedLine]

15. Rao P S, Wilson A D, Chopra P S - Transcatheter closure of atrial septal defect by "buttoned" devices. Am J Cardiol 1992; 69: 1056-61. [MedLine]

Article receive on Saturday, November 30, 1996

CCBY All scientific articles published at www.bjcvs.org are licensed under a Creative Commons license

Indexes

All rights reserved 2017 / © 2024 Brazilian Society of Cardiovascular Surgery DEVELOPMENT BY