Article

lock Open Access lock Peer-Reviewed

38

Views

CLINICAL-SURGICAL CORRELATION

Rastelli procedure with decellularized pulmonary homograft

Ulisses Alexandre Croti; Domingo M Braile; Ana Carolina Leiroz Ferreiro Botelho Maisano KOZAK; Lilian Beani

DOI: 10.1590/S0102-76382006000300018

CLINICAL DATA

The case of a three-year 11-month white female patient, 97 cm tall and weighing 12 kg is reported. She was diagnosed as having truncus arteriosus at 4 months when she underwent a total correction using the Rastelli procedure with a valved cryopreserved homograft tube and closure of the interventricular shunt in another service. Six months after the correction, the infant presented with signs of congestive heart failure including dyspnea on effort, which gradually deteriorated. On this occasion the patient was in a good general state, ruddy, hydrated, dyspneic and acyanotic. Her thorax was symmetrical with ictus cordis at the 5th left intercostal space on the hemiclavicular line. The cardiac rhythm was regular with two clicks and systolic and diastolic murmurs of 2+/4+ at a pulmonary focus. Pulmonary auscultation was symmetrical without adventitious noises. The abdomen was flaccid at 1 cm from the right costal edge. The extremities had symmetrical palpable pulses without pressure differences among the four limbs (90/40 mmHg). The patient was taking furosemide and spirolactone.

ELECTROCARDIOGRAM AND HOLTER MONITORING

An electrocardiogram demonstrated sinus rhythm with a heartbeat of 136 bpm. The ÂP was +30 and the ÂQRS was +120 without direct signs of atrial overload. A complete block of the right branch was identified. There were ventricular repolarization alterations secondary to the block. Holter monitoring demonstrated sinus rhythm with a right branch block, a maximum heartbeat of 155 and a minimum of 73 bpm. Ventricular and supraventricular ectopias were not recorded as no symptoms were identified on the log.

RADIOGRAM

The radiogram showed visceral Situs solitus and a cardiothoracic index of 0.54. The middle arch was slightly bulging; there was slight peripheral hypovolemia, free diaphragmatic domes and the presence of steel threads in the sternum.

ECHOCARDIOGRAM

In the postoperative period of the Rastelli procedure and ventriculoseptoplasty. Slight tricuspid insufficiency was evidenced with significant pulmonary insufficiency, hypoplasia of the pulmonary trunk (PT) and pulmonary arteries with the right pulmonary artery (RPA) 7 mm and the left pulmonary artery (LPA) 6 mm. The gradient between the right ventricle (RV) and the pulmonary arteries was 44 mmHg.

DIAGNOSIS

The echocardiogram demonstrated dysfunction of the RV-PT homograft tube, but with overall functioning of the RV normal, an unfavorable fact for the clinical presentation. A cineangiographic study was requested which confirmed insufficiency of the tube with significant stenosis at the connection of the tube with the RPA and LPA (Figure 1). It also showed that there was no pulmonary hypertension, which was considered important for the new correction of the RV-PT connection.


Fig. 1 - Cineangiographic study. A: stenosis at the origin of the right pulmonary artery (RPA), B: stenosis at the origin of the left pulmonary artery (LPA)


OPERATION

Median transsternal thoracotomy was performed with dissection of adherences and establishment of cardiopulmonary bypass at 25 ºC. Intermittent hypothermic anterograde sanguineous cardioplegia was utilized at 20-minute intervals. Regions of significant stenosis at the origin of the RPA and LPA (Figure 2) were identified and resected. A decellularized homograft tube (Figure 3) was inserted between the pulmonary arteries and the RV using 5-0 polypropylene thread for the anastomoses. The operation was completed using a bovine pericardium patch between the homograft and the incision in the RV (Figure 4). Perfusion time was 154 minutes and the myocardial ischemia time was 125 minutes. We stress that the choice of the decellularized homograft as replacement is directly related to the possibility of better long-term results [1]. An echocardiogram performed eight months following the intervention showed slight to moderate pulmonary valve regurgitation similar to in the immediate postoperative period, without stenosis of the valve or the origin of the pulmonary arteries.


Fig. 2 - Resected tissue from the origin of the pulmonary arteries RPA: right pulmonary artery; LPA: left pulmonary artery


Fig. 3 - Decellularized homograft: Note the thinner and more delicate walls normally seen with cryopreserved homografts


Fig. 4 - Final appearance of the implantation of the decellularized homograft completed with a bovine pericardial patch


REFERENCE

1. Costa FD, Dohmen PM, Duarte D, von Glenn C, Lopes SV, Haggi Filho H et al. Immunological and echocardiographic evaluation of decellularized versus cryopreserved allografts during the Ross operation. Eur J Cardiothorac Surg. 2005;27(4):572-8.

Article receive on Thursday, June 1, 2006

CCBY All scientific articles published at www.bjcvs.org are licensed under a Creative Commons license

Indexes

All rights reserved 2017 / © 2024 Brazilian Society of Cardiovascular Surgery DEVELOPMENT BY